Defining Threshold Values of Encapsulant and Backsheet Adhesion for PV Module Reliability

Nick Bosco, Joshua J. Eafanti, Sarah Kurtz, Jared Tracy, Reinhold H. Dauskardt

IEEE Journal of Photovoltaics · 2017 · 33 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

The width-tapered cantilever beam method is used to quantify the debond energy (adhesion) of encapsulant and backsheet structures of 32 modules collected from the field. The collected population of modules contains both those that have remained intact and those with instances of either or both encapsulant and backsheet delamination. From this survey, initial threshold values (an adhesion value above which a module should remain intact throughout its lifetime) for encapsulant and backsheet interfaces are proposed. For encapsulants this value is ~160 J/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and for backsheets ~10 J/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> . It is expected that these values will continue to be refined and evolve as the width-tapered cantilever beam method gets adopted by the PV industry, and that they may aid in the future improvement of accelerated lifetime tests and the development of new, low-cost materials.

References

5