Physics in Medicine and Biology · 2017 · 45 citations · 44 references
MedicineOncologyRadiation OncologyRadiation DosimetryRadiation ProtectionTreatment PlanningExternal Beam RadiotherapyRadiation TherapyBeam Delivery SystemsCollimator DesignExternal Beam Radiotherapy DosimetryRadiobiological EffectivenessRadiobiological EffectsTherapeutic Dosimetry
Minibeam radiation therapy (MBRT) delivers an ultrahigh dose of x-ray (⩾100 Gy) in 200-1000 µm beams (peaks), separated by wider non-irradiated regions (valleys) usually as a single temporal fraction. Preclinical studies performed at synchrotron facilities revealed that MBRT is able to ablate tumors while maintaining normal tissue integrity. The main purpose of the present study was to develop an efficient and accessible method to perform MBRT using a conventional x-ray irradiator. We then tested this new method both in vitro and in vivo. Using commercially available lead ribbon and polyethylene sheets, we constructed a collimator that converted the cone beam of an industrial irradiator to 44 identical beams (collimator size ≈ 4 × 10 cm). The dosimetry characteristics of the generated beams were evaluated using two different radiochromic films (beam FWHM = 246 ± 32 µm; center-to-center = 926 ± 23 µm; peak-to-valley dose ratio = 24.35 ± 2.10; collimator relative output factor = 0.84 ± 0.04). Clonogenic assays demonstrated the ability of our method to induce radiobiological cell death in two radioresistant murine tumor cell lines (TRP = glioblastoma; B16-F10 = melanoma). A radiobiological equivalent dose (RBE) was calculated by evaluating the acute skin response to graded doses of MBRT and conventional radiotherapy (CRT). Normal mouse skin demonstrated resistance to doses up to 150 Gy on peak. MBRT significantly extended the survival of mice with flank melanoma tumors compared to CRT when RBE were applied (overall p < 0.001). Loss of spatial resolution deep in the tissue has been a major concern. The beams generated using our collimator maintained their resolution in vivo (mouse brain tissue) and up to 10 cm deep in the radiochromic film. In conclusion, the initial dosimetric, in vitro and in vivo evaluations confirmed the utility of this affordable and easy-to-replicate minibeam collimator for future preclinical studies.
44
Clonogenic assay of cells in vitro
Nicolaas A.P. Franken, Hans M. Rodermond, Jan Stap et al. · Nature Protocols · 2006 · 4.2K citations
Radiobiology for the Radiologist.
Annals of Internal Medicine · 1974 · 3.5K citations
Radiation and dual checkpoint blockade activate non-redundant immune mechanisms in cancer
Christina Twyman-Saint Victor, Andrew J. Rech, Amit Maity et al. · Nature · 2015 · 2.4K citations
Medicine, Cancer Biology, Oncology +14
AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Chao Ma, C Coffey, L DeWerd et al. · Medical Physics · 2001 · 819 citations · Full text