Proteinlipid InteractionProtein SecretionImmunocytochemical TechniqueEngineeringBiomedical EngineeringCellular PhysiologyAntibody EngineeringClear Fluorescence SignalMolecular ImagingBiophysicsProtein FunctionTumor TargetingCancer CellsProtein TransportCell BiologyTumor MicroenvironmentDrug TargetingIntracellular TraffickingCellular BiochemistryTight JunctionsMedicine
Claudins (CLs) are membrane proteins found in tight junctions and play a major role in establishing the intercellular barrier. However, some CLs are abnormally overexpressed on tumor cells and are valid clinical biomarkers for cancer diagnosis. Here, we constructed antibody Fab fragment-based Quenchbodies (Q-bodies) as effective and reliable fluorescent sensors for detecting and visualizing CLs on live tumor cells. The variable region genes for anti-CL1 and anti-CL4 antibodies were used to express recombinant Fab fragments, and clones recognizing CL4 with high affinity were selected for making Q-bodies. When two fluorescent dyes were conjugated to the N-terminal tags attached to the Fab, the fluorescent signal was significantly increased after adding nanomolar-levels of purified CL4. Moreover, addition of the Q-body to CL4-expressing cells including CL4-positive cancer cells led to a clear fluorescence signal with low background, even without washing steps. Our findings suggested that such Q-bodies would serve as a potent tool for specifically illuminating membrane targets expressed on cancer cells, both in vitro and in vivo.