Bioanalysis · 2017 · 32 citations · 5 references
PharmacyClinical PharmacokineticsPharmacokineticsDose-response ModelingPharmacokinetic ModelingPopulation PharmacokineticsAntibody CharacterizationAntibody PharmacokineticsBioanalytical Method ValidationResponse AssessmentAntibody Titer AnalysisAssayAssay SensitivityLinearityLinearity AssessmentModel Validation In PharmacokineticsPrecision
BACKGROUND: Titer methods are commonly used to characterize the magnitude of an antidrug antibody response. Assay S/N is an appealing alternative, but the circumstances under which use of signal-to-noise (S/N) is appropriate have not been well defined. RESULTS: We validated both titer and S/N-based methods for several therapeutics. S/N correlated strongly with titer both in aggregate and when examined on a per subject basis. Analysis of impact of antibody magnitude on pharmacokinetics yielded the same result using either method. Each assay demonstrated excellent precision, good linearity, and adequate drug tolerance. CONCLUSION: Under these circumstances, assay S/N is a valid alternative to titer for assessment of the magnitude of an antidrug antibody response.
5
Anthony R. Mire‐Sluis, Yu Chen Barrett, Viswanath Devanarayan et al. · Journal of Immunological Methods · 2004 · 621 citations
Mark A. Kroenke, Dohan Weeraratne, Hongjie Deng et al. · Journal of Immunological Methods · 2017 · 19 citations