International Journal of Energetic Materials and Chemical Propulsion · 2017 · 10 citations · 0 references
EngineeringChemical EngineeringMaterials ScienceCombustionElectrochemistryEnergy MaterialsCombustion FundamentalsCombustion ProcessesFuel CharacteristicsFuel ChemistryOxidizer EffectsPropellant ChemistryBurning RateCombustion BehaviorCombustion ChemistryDry Storage ConditionsElectric Field EffectsPerchlorate SaltsSolid Propellants
An experimental study of the electric effects on the combustion behavior of ammonium nitrate (AN)-based solid propellants has been conducted. A noticeable effect of the applied voltage on the flame behavior and the burning rate was observed. The burning rate showed an increase by a factor of 3 to 5 when applying voltage as high as 250 V. Propellant storing conditions were found significant, revealing a greater electricity effect for propellant strands exposed to ambient (humid) environment than for those stored in the desiccator's dry conditions. Propellants based on ammonium perchlorate (AP) oxidizer were not affected by the application of an electric field.