Ultrasound evaluation of the rotator cuff after osteosynthesis of proximal humeral fractures with locking intramedullary nail

Mauro Emílio Conforto Gracitelli, Eduardo Angeli Malavolta, Jorge Henrique Assunção, Bruno Akio Matsumura, Kodi Edson Kojima, Arnaldo Amado Ferreira Neto

Revista Brasileira de Ortopedia (English Edition) · 2017 · 13 citations · 25 references

DOIFull text

Open access

Concepts

Abstract

OBJECTIVE: To evaluate supraspinatus tendon integrity with ultrasound (US) in patients submitted to proximal humeral fracture (PHF) fixation with a locking intramedullary nail. METHODS: Thirty-one patients with PHF treated with curvilinear locking intramedullary nail, aged between 50 and 85 years, were assessed by US at six months postoperatively and clinically at six and 12 months postoperatively. The primary aim was supraspinatus tendon integrity, evaluated by US at six months postoperatively. Secondary aims included the Constant-Murley, DASH score, and visual analog pain scores, as well as complications and reoperation rates. RESULTS: = 0.336). Complications, exclusively for rotator cuff ruptures, were observed in nine patients (29%). CONCLUSION: A high rate of rotator cuff ruptures was demonstrated, with partial ruptures in 32% of cases and full-thickness ruptures in 13%. However, clinical results are satisfactory, and are not influenced by the presence of rotator cuff ruptures.

References