Radiotherapy and Oncology · 2017 · 30 citations · 25 references
MedicineOncologyRadiation OncologyClinical Radiation OncologySurgical OncologyTreatment PlanningComputed TomographyExternal Beam RadiotherapyRadiation TherapyRadiation Therapy For Prostate DiseaseRadiobiological ConsiderationsVirtual Treatment PlanningCost-effectivenessExternal Beam Radiation CareProstate Cancer RadiotherapyRectal Spacer UseSpacer DesignSpacer SystemsSpacer TechnologyVirtual Implant Placement
INTRODUCTION: Previous studies have shown that the implantable rectum spacer (IRS) is not beneficial for all patients. A virtual IRS (V-IRS) was constructed to help identify the patients for whom it is cost-effective to implant an IRS, and its viability as a tool to tailor the decision of an IRS implantation to be beneficial for the specified patient was assessed. Please watch animation: (https://www.youtube.com/watch?v=tDlagSXMKqw) MATERIALS AND METHODS: The V-IRS was tested on 16 patients: 8 with a rectal balloon implant (RBI) and 8 with a hydrogel spacer. A V-IRS was developed using 7 computed tomography (CT) scans of patients with a RBI. To examine the V-IRS, CT scans before and after the implantation of an IRS were used. IMRT plans were made based on CT scans before the IRS, after IRS and with the V-IRS, prescribing 70 Gray (Gy) to the planning target volume. Toxicity was accessed using externally validated normal tissue complication probability (NTCP) models, and the Cost-effectiveness was analyzed using a published Markov model. RESULTS: The rectum volume receiving 75Gy (V75) were improved by both the IRS and the V-IRS with on average 4.2% and 4.3% respectively. The largest NTCP reduction resulting from the IRS and the V-IRS was 4.0% and 3.9% respectively. The RBI was cost-effective for 1 out of 8 patients, and the hydrogel was effective for 2 out of 8 patients, and close to effective for a third patient. The classification accuracy of the model, regarding cost-effectiveness, was 100%. CONCLUSION: The V-IRS approach in combination with a toxicity prediction model and a cost-effectiveness analyses is a promising basis for a decision support tool for the implantation of either a hydrogel spacer or a rectum balloon implant.
25
Neil Mariados, John Sylvester, Dhiren Shah et al. · International Journal of Radiation Oncology*Biology*Physics · 2015 · 423 citations · Full text
R. de Crevoisier, Susan L. Tucker, Lei Dong et al. · International Journal of Radiation Oncology*Biology*Physics · 2005 · 389 citations
Patrick A. Kupelian, Twyla R. Willoughby, C.A. Reddy et al. · International Journal of Radiation Oncology*Biology*Physics · 2007 · 371 citations