ULTRASONOGRAPHY · 2017 · 85 citations · 18 references
Veterinary MedicineRadiologyDiagnostic ImagingUltrasonographyUltrasoundBreast UltrasonographyBreast UltrasoundDiagnostic UltrasonographyUltrasonicsUltrasound ImagingBreast Ultrasound ReportingComparative Diagnostic PerformanceDiagnostic Breast UltrasonographyDiagnostic Breast UltrasoundDiagnostic Performance MetricsResearch ArticlesState-of-the-art Review
PURPOSE: The purpose of this study was to evaluate the usefulness of applying computer-aided diagnosis (CAD) to breast ultrasound (US), depending on the operator's experience with breast imaging. METHODS: Between October 2015 and January 2016, two experienced readers obtained and analyzed the grayscale US images of 200 cases according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon and categories. They additionally applied CAD (S-Detect) to analyze the lesions and made a diagnostic decision subjectively, based on grayscale US with CAD. For the same cases, two inexperienced readers analyzed the grayscale US images using the BI-RADS lexicon and categories, added CAD, and came to a subjective diagnostic conclusion. We then compared the diagnostic performance depending on the operator's experience with breast imaging. RESULTS: The sensitivity values for the experienced readers, inexperienced readers, and CAD (for experienced and inexperienced readers) were 91.7%, 75%, 75%, and 66.7%, respectively. The specificity values for the experienced readers, inexperienced readers, and CAD (for experienced and inexperienced readers) were 76.6%, 71.8%, 78.2%, and 76.1%, respectively. When diagnoses were made subjectively in combination with CAD, the specificity significantly improved (76.6% to 80.3%) without a change in the sensitivity (91.7%) in the experienced readers. After subjective combination with CAD, the sensitivity and specificity improved in the inexperienced readers (75% to 83.3% and 71.8% to 77.1%). In addition, the area under the curve improved for both the experienced and inexperienced readers (0.84 to 0.86 and 0.73 to 0.8) after the addition of CAD. CONCLUSION: CAD is more useful for less experienced readers. Combining CAD with breast US led to improved specificity for both experienced and inexperienced readers.
18
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Computerized detection and classification of cancer on breast ultrasound1
Karen Drukker, Maryellen L. Giger, Carl J. Vyborny et al. · Academic Radiology · 2004 · 106 citations