Perfusion · 2017 · 43 citations · 31 references
MedicineHematologyPediatricsHemostasisPediatric Clinical PharmacologyPediatric HematologyAnticoagulant TherapyAnticoagulation TherapyAntithrombotic TherapyCoagulation DisordersPediatric ThrombosisThrombosisActivated Clotting TimeAntithrombin FunctionCoagulation Scoring SystemsGlobal Coagulation TestingHeparin AnticoagulationMonitoring Of Anticoagulant TherapyPediatric HemostasisThrombotic Complication Monitoring
Objectives: Extracorporeal Life Support (ECLS) risks thrombotic and hemorrhagic complications. Optimal anti-coagulation monitoring is controversial. We compared coagulation tests evaluating the heparin effect in pediatric ECLS. Methods: A retrospective study of children (<18yrs) undergoing ECLS over 12 months in a tertiary pediatric intensive care unit (PICU). Variables included anti-Factor Xa activity (anti-Xa), activated partial thromboplastin time (aPTT), activated clotting time (ACT) and thromboelastogram (TEG ® 6s) parameters: ratio and delta reaction (R) times (the ratio and difference, respectively, between R times in kaolin assays with and without heparinase). Test results were correlated with unfractionated heparin infusion rate (IU/kg/hr) at the time of sampling. Mean test results of each ECLS run were evaluated according to the presence/absence of complications. Results: Thirty-two ECLS runs (31 patients) generated 695 data-points for correlation. PICU mortality was 22% and the thrombotic complication rate was 66%. The proportion of variation in coagulation test results explained by heparin dose was 13.3% for anti-Xa, 11.9% for ratio R time, and 9.9% for delta R time, compared with <1% for ACT and aPTT. Incorporating individual variation, age and antithrombin activity in a model with heparin dose explained less than 50% of the variation in test results. Correlation varied according to age, day of ECLS run and between individuals, with parallel dose-response lines noted between patients. Significantly lower mean anti-Xa was observed in PICU non-survivors and runs with thrombosis. Conclusion: Lower anti-Xa was observed in ECLS runs with complications. Although absolute results from anti-Xa and TEG6 ® s showed the best correlation with heparin dose, a large proportion of variation in results was unexplained by heparin, while dose response was similar between individuals. Population pharmacokinetic/pharmacodynamic modelling is required, as well as prospective trials to delineate the superior means of adjusting heparin therapy to prevent adverse clinical outcomes.
31
A Cell-based Model of Hemostasis
Dougald M. Monroe, Maureane Hoffman · Thrombosis and Haemostasis · 2001 · 1.5K citations
Heparin and Low-Molecular-Weight Heparin
Jack Hirsh, Robert Raschke · CHEST Journal · 2004 · 961 citations
Paediatric Index of Mortality 3
Lahn Straney, Archie Clements, Roger Parslow et al. · Pediatric Critical Care Medicine · 2013 · 484 citations