2004 · 10 citations · 0 references
EngineeringMining EngineeringDrillingMine HealthMine SafetyNoiseNoise Exposure ControlNoise-induced Hearing DamageNoise-induced Hearing Loss PreventionOccupational Health In MiningOccupational Noise ExposureDrill SpeedNoise EmissionsNoise Source CharacterizationOccupational Health And Safety In DrillingOccupational Noise AssessmentOccupational Noise Exposure AssessmentRoof Bolting MachinesWorkplace Noise Exposure
The National Institute for Occupational Safety and Health (NIOSH) has initiated a study of a roof bolter to reduce noise exposure to mine roof-bolter operators. An important segment of this research entails determining the affect of various drilling configurations on the performance (penetration rate) and sound power emissions when drilling into granite. Test conditions included using various combinations of rotational speeds and thrusts, using 2.54and 3.49-mm(1and 1 3/8-in.-) diameter hexagonal and round drill steels, using vacuum and wet conditions and using drill media of differing compressive strengths. This paper details the affects of each of these variables on the performance and sound power level emission. When drilling into granite, it was found that wet drilling generated lower sound power levels and performed better than vacuum drilling. Introduction Noise is one of the most pervasive health hazards in mining. NIOSH identified occupational noise-induced hearing loss (NIHL) as one of the ten leading work-related diseases and injuries. Mine Safety and Health Administration coal noise sample data (Title 30 CFR, Part 62) collected from 2000 to 2002 show that 65% of the equipment whose operators exceeded 100% dosage comprise only seven different types of machines: auger miners, bulldozers, continuous miners, front end loaders, roof bolters, shuttle cars (electric) and trucks (MSHA, 2000-2002). In addition, the MSHA data indicate that the roof bolter is third among all the equipment and second among equipment in underground coal mines whose operators exceed 100% dosage (Fig. 1). This paper presents results from a project that forms part of the latest effort by NIOSH’s Pittsburgh Research Laboratory (PRL) to control noise exposure in mining environments. Specifically, this paper concentrates on the noise emissions during the drilling cycle of a roof-bolting machine. This information is available for reference to designers of mining equipment, mining companies and MSHA. Background Underground drilling is subject to many variables that can affect noise emissions. Some of these variables, such as the acoustic environment, the geometry and composition of the surfaces, the mine shape and the compressive strength of the drill medium, cannot be controlled. Other variables such as drill steel shape and bit size are controlled by the operator. The acoustic environment that the mining machines operate in is a critical factor in influencing the sound pressure levels to which workers are exposed. Underground mines are enclosed areas with reverberant sound fields. The geometry and the composition of the surfaces influence the overall sound level by reflecting or absorbing the incident sound energy. The compressive strength of the media being drilled affects the acoustic absorption properties of the mine environment. Harder media, with compressive strengths above 138 MPa (20,000 psi), reflect more acoustic energy than softer media, i.e., less than 83 MPa (12,000 psi) compressive strength. The operator is responsible for controlling the roof bolter, which may directly or indirectly affect the overall noise level generated while drilling. Thrust levels and rotation speeds supplied to the drill will also affect the sound power emissions. Variations of the thrust and rotation speed in different media will affect the performance of the drill, which is indirectly related to the sound power level emissions. For instance, stalling or jamming of the drill bit because of incorrect thrust levels or rotation speeds will create an increased sound power emission. Using the manufacturers recommended settings of the roof bolter for the drill media would enhance the performance of the drill, penetration rate and directly affect the sound pressure levels to which workers are exposed. The roof bolter has several noise sources that may be considered worthy of examination. These include the vacuum pump, hydraulic pumps, drill chuck, drill steel and drill bit. The vacuum pump, hydraulic pumps and drill chuck will vary for different drill manufacturers. Both vacuum and hydraulic pumps contributes some to overall noise emissions. However, early tests at PRL confirmed that the hydraulic and vacuum pumps are not a major noise source for roof bolters. Drill steels are manufactured either in hexagonal or round shapes. The steel can be manufactured at any length, but typical lengths are 1.2, 1.8 and 2.4 m (4, 6 and 8 ft). Bits are available in several types, usually designed for either wet or vacuum drilling. The sharpness of the drill bit will have considerable effect on the performance of the bolter, which will influence the sound power levels generated. Wet drilling, as opposed to vacuum, was expected to generate a lower sound power level because water attenuates higher frequency noise. These concerns prompted NIOSH to perform research to determine the effects of each of these factors on the performance and sound power emissions when drilling. Technical approach Sound levels to which roof bolter operators are exposed are determined by the sound power radiated from the drilling process and by the acoustic characteristics of the mine environment. The sound power is the quantity of most interest because it is a fundamental property of the drilling process and can be used for comparative purposes of differing drilling configurations independent of acoustical environmental conditions in any specific mine environment. Additionally, once the sound power level is determined, it is possible to predict the sound pressure level that the operator will be exposed to once the acoustic characteristics of the mine environment are understood. Sound level prediction research of this type is currently in development at PRL and is beyond the scope of this paper. Test plan Given the variation in underground mines, both geometrical and acoustical, it is difficult to achieve uniform test conditions. Therefore, testing was conducted in a reverberation chamber at PRL. This allows sound power-level determination in a known acoustic environment, and the results are independent of the variables associated with the acoustic properties of underground mines. Environmental conditions in the test chamber are controlled so as to not influence test results in excess of the uncertainty stated below. The key environmental condition to control is relative humidity, which is controlled via humidifiers. The relative humidity is maintained above 65% at all times, so as to not affect the data at higher frequencies, i.e., 1,000 Hz or greater. A survey of acoustics standards detailing accepted procedures for determining sound power levels in hard walled or reverberant test chambers led to the selection of ISO 3743-2 (ISO, 1994) as the industry standard around which the testing was based. The objective is to ensure that sound power determinations are sufficiently repeatable to allow detection of changes in emissions due to the various test conditions and sufficiently reproducible to allow the data to be used for meaningful sound pressure level prediction in real mine environments. Measurement repeatability is a measure of the ability of laboratory to get the same result on the same test specimen within the laboratory and is determined through repeatability studies conducted by the laboratory. Measurement reproducibility is a measure of the uncertainly associated with test results from different laboratories and is stated in the test standard based on round robin studies conducted amongst acoustics laboratories. The ISO 3743-2 test method has a stated standard deviation of reproducibility of 2.0 dBA, with uncertainty as a function of frequency as shown in Table 1. Internal quality-assurance studies in the PRL reverberant test facility for well-behaved sources indicated that the standard deviation of repeatability in the laboratory is on the order of 0.25 dBA. As the 95% uncertainly interval associated with both the repeatability and reproducibility of the method is estimated at 1.96 times the standard deviation, the PRL measurement program is capable of detecting changes to the sound power emissions of a specific device on the order of 0.5 dB and to determine the true value of the sound power emissions with an uncertainty of about 4 dBA. A Bruel and Kjaer pulse system served as the data-acquisition system for the sound power-level determinations associated with this research. One-third octave band sound pressure levels are collected by the pulse system at 15 microphone locations within the reverberation chamber and these data are dynamically linked to an Excel spreadsheet in real time. In Excel, these data are logarithmically averaged to calculate an average sound pressure level for the test. These measurements are conducted for a calibrated reference sound source and then on the device Figure 1 — MSHA coal noise sample data — percentage of equipment whose operators exceeded 100% dose. *Applicable to a relatively flat spectrum from 100 through 10 kHz. 125 5.0