Medical Physics · 2017 · 29 citations · 33 references
MedicineRadiation OncologyRadiologyDiagnostic ImagingDiagnostic RadiologyTreatment PlanningChest RadiographyComputed TomographyNuclear Medicine ImagingRadiographic ImagingContrast-enhanced Computed TomographyDose PlanningDual-energy Computed TomographyLung Function TestingLung Volume AssessmentLung Volume EstimationLung Volume InterpretationPulmonary Functional Imaging
PURPOSE: There is an increasing interest in the evaluation of lung function from physiological images in radiation therapy treatment planning to reduce the extent of postradiation toxicities. The purpose of this work was to retrieve reliable functional information from contrast-enhanced dual-energy computed tomography (DECT) for new applications in radiation therapy. The functional information obtained by DECT is also compared with other methods using single-energy CT (SECT) and single-photon emission computed tomography (SPECT) with CT. The differential function between left and right lung, as well as between lobes is computed for all methods. METHODS: Five lung cancer patients were retrospectively selected for this study; each underwent a SPECT/CT scan and a contrast-injected DECT scan, using 100 and 140 Sn kVp. The DECT images are postprocessed into iodine concentration maps, which are further used to determine the perfused blood volume. These maps are calculated in two steps: (a) a DECT stoichiometric calibration adapted to the presence of iodine and followed by (b) a two-material decomposition technique. The functional information from SECT is assumed proportional to the HU numbers from a mixed CT image. The functional data from SPECT/CT are considered proportional to the number of counts. A radiation oncologist segmented the entire lung volume into five lobes on both mixed CT images and low-dose CT images from SPECT/CT to allow a regional comparison. The differential function for each subvolume is computed relative to the entire lung volume. RESULTS: The differential function per lobe derived from SPECT/CT correlates strongly with DECT (Pearson's coefficient r = 0.91) and moderately with SECT (r = 0.46). The differential function for the left lung shows a mean difference of 7% between SPECT/CT and DECT; and 17% between SPECT/CT and SECT. The presence of nonfunctional areas, such as localized emphysema or a lung tumor, is reflected by an intensity drop in the iodine concentration maps. Functional dose volume histograms (fDVH) are also generated for two patients as a proof of concept. CONCLUSION: The extraction of iodine concentration maps from a contrast-enhanced DECT scan is achieved to compute the differential function for each lung subvolume and good agreement is found in respect to SPECT/CT. One promising avenue in radiation therapy is to include such functional information during treatment planning dose optimization to spare functional lung tissues.
33
EANM guidelines for ventilation/perfusion scintigraphy
Marika Bajc, J. B. Neilly, Massimo Miniati et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2009 · 350 citations · Full text
Lung Perfusion with Dual-energy Multidetector-row CT (MDCT)
François Pontana, Jean‐Baptiste Faivre, Martine Rémy‐Jardin et al. · Academic Radiology · 2008 · 234 citations