Journal of Magnetic Resonance Imaging · 2017 · 27 citations · 35 references
MedicineOncologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDiffusion ImagingLung CancerMedical ImagingThoracic Oncology ImagingTumor CharacterizationTumor ImagingApparent Diffusion Coefficient AnalysisDiffusion Coefficient EstimationIntraclass CorrelationIntravoxel Incoherent Motion ImagingLung Tumor ImagingReproducibility AnalysisReproducibility AssessmentTumor Diffusion Imaging
PURPOSE: To prospectively evaluate the short-term reproducibility of intravoxel incoherent motion (IVIM) parameters and apparent diffusion coefficient (ADC) in lung cancer patients. MATERIALS AND METHODS: ) scans twice (0.5-1-hour interval) at 3T. Regions of interests (ROIs) were drawn on ADC maps and IVIM images to derive the mean ADC value and IVIM parameters D, D*, and f. Intra- and interobserver, test-retest reproducibility were assessed with intraclass correlation coefficients (ICCs), within coefficient-of-variations (WCVs), and Bland-Altman analysis. The effects of type, size, and location of lung lesions were compared with WCVs. RESULTS: D and ADC showed good intraobserver reproducibility and interobserver agreement, while D* and f showed relatively larger variability (WCV 20.89-34.97%). The test-retest reproducibility of D and ADC were good (ICC 0.763-0.837; WCV 11.12-12.55%), while those of D* and f were relatively poor (ICC 0.604-0.842; WCV 36.54-72.62%). D and ADC had decreased reproducibility for lesions <2 cm (WCV 14.20%, 16.34%, respectively) and for lesions in the lower lung zones (WCV 16.52%, 14.78%, respectively). f had decreased reproducibility in central lung cancers (WCV 50.11%) and lesions >2 cm (WCV 42.64%). D* had even worse reproducibility in peripheral lung cancers (WCV 84.11%) and lesions in the lower lung zones (WCV 80.84%). CONCLUSION: If the change in ADC, D, D*, and f values is less than ∼31%, 34%, 170%, and 130%, respectively, it may be caused by measurement error. The type, size, and location of lung lesions have an effect on measurement errors. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2018;47:1003-1012.
35
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Denis Le Bihan, D Lallemand, Michèle Aubin et al. · Radiology · 1988 · 3.2K citations
Adrian Andreou, Dow‐Mu Koh, David J. Collins et al. · European Radiology · 2012 · 285 citations
Stéphanie Nougaret, Hebert Alberto Vargas, Yulia Lakhman et al. · Radiology · 2016 · 158 citations