British Journal of Ophthalmology · 2017 · 149 citations · 24 references
Health ProfessionsOphthalmologyVision ScienceOcular AnatomyOcular DiseaseOcular ImagingEye ExaminationGlaucomaOptical Coherence TomographyRetinal ExaminationRetinal ImagingMacular Pigment DensityOcular Vascular AssessmentOptic Nerve Head EvaluationOptical Coherence Tomography AngiographyRepeatability ModelsSignal Strength EvaluationWithin-subject CorrelationWithin-subject Variance
AIMS: To compare the intrasession repeatability of peripapillary and macular vessel density measurements of optical coherence tomography angiography (OCTA) in normal and glaucoma eyes, and to evaluate the effect of signal strength of OCTA scans on the repeatability. METHODS: In a cross-sectional study, three optic nerve head scans each of 65 eyes (30 normal, 35 glaucoma eyes) and three macular scans each of 69 eyes (35 normal, 34 glaucoma eyes) acquired in the same session with OCTA were analysed. Repeatability was assessed using within-subject coefficient of repeatability (CRw) and variation (CVw). Effect of signal strength index (SSI) on repeatability was evaluated with repeated-measures mixed-effects models. RESULTS: CRw (%) and CVw (%) of peripapillary measurements in normal eyes ranged between 3.3 and 7.0, and 2.5 and 4.4 respectively, and that in glaucoma eyes between 3.5 and 7.1, and 2.6 and 6.6. For the macular, these measurements ranged between 4.1 and 6.0, and 3.3 and 4.7 in normal eyes and 4.3 and 6.9, and 3.7 and 5.6 in glaucoma eyes. Repeatability estimates of most measurements were similar in normal and glaucoma eyes. Vessel densities of both peripapillary and macular regions significantly increased with increase in SSI of repeat scans (coefficients ranging from 0.15 to 0.38, p<0.01 for all associations). CONCLUSIONS: Repeatability estimates of OCTA measured peripapillary and macular vessel densities were similar in normal eyes and eyes with glaucoma. SSI values of the scans had a significant effect on the repeatability of OCTA with the vessel density values increasing in scans with higher SSI values.
24
Statistics Notes: Measurement error
J M. Bland, D. G Altman · BMJ · 1996 · 1.1K citations · Full text
Health Professions, Biostatistics, Individual Differences +16
IMAGE ARTIFACTS IN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY
Richard F. Spaide, James G. Fujimoto, Nadia K. Waheed · Retina · 2015 · 1K citations · Full text
Statistics notes: Measurement error
J Martin Bland · BMJ · 1996 · 832 citations · Full text
Health Professions, Biostatistics, Individual Differences +16
Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
Yali Jia, Eric Wei, Xiaogang Wang et al. · Ophthalmology · 2014 · 739 citations · Full text