Parastomal Hernia Repair with a 3D Funnel Intraperitoneal Mesh Device and Same‐Sided Stoma Relocation: Results of 56 Cases
26
Citations
17
References
2017
Year
PSH repair with 3D funnel mesh in IPOM technique is safe, efficient and easy to perform in laparoscopic and open surgical approaches providing advantageous results compared to other techniques. Furthermore, simultaneous detection and treatment of concomitant incisional hernias has shown favorable. However, the mesh funnel distends and becomes shortened encasing a bulky bowel mesentery and further shrinkage happens eccentric. Changing mesh construction according to lengthening the funnel could possibly lead to reduction in recurrence.