Journal of Bronchology & Interventional Pulmonology · 2017 · 10 citations · 14 references
MedicineClinical SciencesPathologyPulmonologyUltrasonographyUltrasoundChest RadiologyDiagnostic UltrasonographyFine-needle Aspiration CytologyThoracic UltrasonographyThoracic UltrasoundUltrasound-guided ProceduresDiagnostic Test YieldDiagnostic Yield AssessmentEnlarged Lymph NodesFna CytologyLung Cancer CytologyLymph Node Fine-needle Aspiration CytologyMediastinal Fine-needle Aspiration CytologyTransbronchial Cytologic Sampling
BACKGROUND: The diagnostic yield of conventional transbronchial needle aspiration (TBNA) is characterized by a learning effect. The aim of this retrospective study was to verify whether a learning curve similarly affected the yield of endobronchial ultrasound-guided (EBUS)-TBNA. To this end, we evaluated the sensitivity and diagnostic accuracy of EBUS-TBNA during the first 3 years of activity. METHODS: EBUS-TBNA was performed by 2 operators with no previous experience in this technique. Cytologic samples were obtained from mediastinal and hilar lymph nodes enlarged at a chest computed tomography scan and/or with increased fluorodeoxyglucose uptake at computed tomography/positron emission tomography scan in patients with suspected lung cancer. The cytologic diagnosis of EBUS-TBNA samples has been compared with the final diagnosis obtained from further diagnostic procedures, surgery, or clinical-radiologic follow-up. RESULTS: From October 2012 to October 2015, we collected 408 EBUS-TBNA cytologic samples from 313 patients: 223 samples were positive for metastatic involvement and 185 were nonmetastatic. The latter included 137 true-negative and 48 false-negative results. The final diagnosis comprised 271 metastatic and 137 nonmetastatic lymph nodes. The overall sensitivity for cancer was 82% and diagnostic accuracy was 88%. Sensitivity and accuracy per year were as follows: first year, 78% and 82% in 90 nodal samples; second year, 83% and 89% in 144 nodal samples; third year, 85% and 91% in 174 nodal samples. CONCLUSIONS: EBUS-TBNA can be considered as a reliable tool even if performed by operators without previous experience in this procedure, and the diagnostic yield continues to increase progressively over a long time.
14
Methods for Staging Non-small Cell Lung Cancer
Gerard A. Silvestri, Anne V. Gonzalez, Michael A. Jantz et al. · CHEST Journal · 2013 · 1.5K citations
Learning curves for endobronchial ultrasound using cusum analysis
Samuel V. Kemp, S. H. El Batrawy, Richard Harrison et al. · Thorax · 2010 · 158 citations · Full text
Mohsen Davoudi, Henri G. Colt, Kathryn Osann et al. · American Journal of Respiratory and Critical Care Medicine · 2012 · 102 citations