EngineeringElectrical EngineeringPower ElectronicsRenewable Energy SystemsTime Series AnalysisControl ChartsDiagnosisFault DetectionFault DiagnosisSolar Energy SystemsSolar Photovoltaic SystemsExponential Weighted Moving AverageExponentially Weighted Moving Average ChartsPhotovoltaic Fault DiagnosisPhotovoltaic System ModelingPhotovoltaic SystemsReal-time ProcessingShort-circuit CurrentSolar Photovoltaic Power Systems
This paper reports a development of a statistical approach for fault detection and diagnosis in a PV system. Specifically, the overarching goal of this work is to early detect and identify faults on the DC side of a PV system (e.g., short-circuit faults; open-circuit faults; and partial shading faults). Towards this end, we apply exponentially-weighted moving average (EWMA) control chart on the residuals obtained from the one-diode model. Such a choice is motivated by the greater sensitivity of EWMA chart to incipient faults and its low-computational cost making it easy to implement in real time. Practical data from a 3.2 KWp photovoltaic plant located within an Algerian research center is used to validate the proposed approach. Results show clearly the efficiency of the developed method in monitoring PV system status.
19
On the performance of artificial bee colony (ABC) algorithm
Derviş Karaboğa · Applied Soft Computing · 2007 · 3.7K citations
Introduction to Statistical Quality Control
Technometrics · 2005 · 955 citations
Renewable energy: sources for fuels and electricity
Choice Reviews Online · 1993 · 534 citations
Engineering, Environmental Engineering, Energy Materials +11
Control Chart Tests Based on Geometric Moving Averages
S. W. Roberts · Technometrics · 1959 · 483 citations