Journal of Oral Science · 2017 · 21 citations · 22 references
DentistryImplant DentistryMaterials EngineeringBone AugmentationImplant SurgeryProsthodontic MaterialsImplant BiomechanicsImplant DesignImplant MaterialsPeri-implant Tissue HealthBiomechanics Of Implant-supported OverdenturesBone-to-implant ContactImplant-bone InteractionPeri-implant Tissue BiomechanicsPeri-implant Tissue StabilityStress ReductionUltraviolet Light TreatmentVertical Loading
Previous finite element analyses of peri-implant stress assumed a bone-implant contact (BIC) ratio of 100%, even though the BIC ratio is known to be approximately 50% or less. However, the recent development of ultraviolet treatment of titanium immediately before use, known as photofunctionalization, significantly increased the BIC ratio, to 98.2%. We used a unique finite element analysis model that enabled us to examine the effects of different BIC ratios on peri-implant stress. A three-dimensional model was constructed under conditions of vertical or oblique loading, an implant diameter of 3.3, 3.75, or 5.0 mm, and a BIC ratio of 53.0% or 98.2%. Photofunctionalization and larger implant diameters were associated with reduced stress on surrounding tissues. Under vertical loading, photofunctionalization had a greater effect than increased implant diameter on stress reduction. Under oblique loading, increased implant diameter had a greater effect than photofunctionalization on stress reduction.
22
L Baggi, Ilaria Cappelloni, M Di Girolamo et al. · Journal of Prosthetic Dentistry · 2008 · 530 citations · Full text