The efficiency of otoacoustic emissions and pure-tone audiometry in the detection of temporary auditory changes after exposure to high sound pressure levels

Samanta Marissane da Silva Barros, Silvana Frota, Ciríaco Cristóvão Tavares Atherino, Francisco Osterne

Brazilian Journal of Otorhinolaryngology · 2007 · 12 citations · 3 references

DOIFull text

Open access

Concepts

Abstract

UNLABELLED: Exposure to noise has a harmful effect on the auditory health of workers. AIM: The main goal of this paper was to establish the role of pure-tone audiometry and evoked transient otoacoustic emissions in the detection of small temporary auditory changes after exposure to high sound pressure levels. STUDY DESIGN: A cross-sectional cohort study. MATERIAL AND METHODS: 30 otologically normal subjects aged between 20 and 35 years were submitted to pure-tone audiometry and evoked transiente otoacoustic emissions before and after 5 hours of exposure to high sound pressure levels (between 80 and 90 dB). RESULTS: For pure-tone audiometry the largest changes occurred at high frequencies--from 3 KHz to 8 KHz after exposure. The evoked transient otoacoustic emissions showed reduced reproductibility from 1 KHz to 4 KHz after exposure to noise. CONCLUSION: We noted that both pure-tone audiometry and evoked transient otoacoustic emissions had a role in detecting statistically significant changes in the auditory threshold and in reproductibility, after exposure to high sound pressure levels.

References

3