Polymer Engineering and Science · 2017 · 19 citations · 5 references
EngineeringBioengineeringBiomedical EngineeringHistologyTissue EngineeringUltrasoundAcoustic ImagingDecellularized Tissue ScaffoldsRegenerative ScaffoldsTissue Engineering ScaffoldsUltrasonicsUltrasound ImagingBulk MorphologyNatural Biomaterial ScaffoldsPolymer ScaffoldsPolymer-based ScaffoldsPolymeric ScaffoldsScaffold CharacterizationUltrasonic MicroscopyUltrasound-based Tissue Characterization
The aim of this article is to verify the applicability of impulse acoustic microscopy as a tool for evaluating scaffolds in tissue engineering. Decellularized rat diaphragms and nonwoven polymer scaffolds made from cellulose diacetate, chlorinated polyvinyl chloride, and polysulfone were used as model objects. Optical microscopy, scanning electron microscopy, and histological research were used as reference methods in order to realize feasibility of the acoustic microscopy method in a regenerative medicine field. Direct comparison of different methods was carried out. The high frequency ultrasound microscopy is defined as a useful non‐invasive tool for studying and investigating the bulk morphology and bulk structure of opaque scaffolds, which allows to diagnose and to assume heterogeneous regions and defects inside the specimens. POLYM. ENG. SCI., 57:709–715, 2017. © 2017 Society of Plastics Engineers
5
Orthotopic transplantation of a tissue engineered diaphragm in rats
Sebastian Sjöqvist, Mei Ling Lim, Neus Feliu et al. · Biomaterials · 2015 · 50 citations