Journal of Orthopaedic Research® · 2017 · 55 citations · 35 references
EngineeringBioengineeringBiomedical EngineeringBiomaterialsBone AugmentationTissue EngineeringBone CementsBone FormationBone RegenerationBone SubstitutesBone TissueBone Tissue EngineeringBone Defect RepairBone Regeneration ScaffoldsCalcium Phosphate Bone SubstitutesCalcium Phosphate CementsCement-based Bone SubstitutesPorous Calcium Phosphate ScaffoldsPorous ScaffoldsStrontium Salts
Calcium phosphate cements (CPCs) are widely used for bone-defect treatment. Current developments comprise the fabrication of porous scaffolds by three-dimensional plotting and doting using biologically active substances, such as strontium. Strontium is known to increase osteoblast activity and simultaneously to decrease osteoclast resorption. This study investigated the short- and long-term in vivo performances of strontium(II)-doted CPC (SrCPC) scaffolds compared to non-doted CPC scaffolds after implantation in unloaded or load-bearing trabecular bone defects in sheep. After 6 weeks, both CPC and SrCPC scaffolds exhibited good biocompatibility and osseointegration. Fluorochrome labeling revealed that both scaffolds were penetrated by newly formed bone already after 4 weeks. Neither strontium doting nor mechanical loading significantly influenced early bone formation. In contrast, after 6 months, bone formation was significantly enhanced in SrCPC compared to CPC scaffolds. Energy dispersive X-ray analysis demonstrated the release of strontium from the SrCPC into the bone. Strontium addition did not significantly influence material resorption or osteoclast formation. Mechanical loading significantly stimulated bone formation in both CPC and SrCPC scaffolds after 6 months without impairing scaffold integrity. The most bone was found in SrCPC scaffolds under load-bearing conditions. Concluding, these results demonstrate that strontium doting and mechanical loading additively stimulated bone formation in CPC scaffolds and that the scaffolds exhibited mechanical stability under moderate load, implying good clinical suitability. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:106-117, 2018.
35
Three‐dimensional printing of porous ceramic scaffolds for bone tissue engineering
Hermann Seitz, Wolfgang Rieder, Stephan Irsen et al. · Journal of Biomedical Materials Research Part B Applied Biomaterials · 2005 · 734 citations · Full text
Engineering, Biomedical Engineering, Materials Engineering +17
Influence of size and stability of the osteotomy gap on the success of fracture healing
L. Claes, Peter Augat, G. Suger et al. · Journal of Orthopaedic Research® · 1997 · 544 citations
Injectability of calcium phosphate pastes
Marc Bohner, Gamal Baroud · Biomaterials · 2004 · 391 citations