MedicineRadiation OncologyRadiation DosimetryRadiation ProtectionTreatment PlanningPatient-specific DosimetryRadiation Dose FractionationRadiation TherapyRadiation Treatment PlanningStereotactic RadiotherapyTreatment Planning Dose CalculationFractionationFractionation In Stereotactic RadiotherapyFractionation Schedule OptimizationStereotactic Body Radiotherapy DosimetryStereotactic Treatment PlanningTreatment Planning DosimetryVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
The dosimetric leaf gap (DLG) is a beam configuration parameter used in the Varian Eclipse treatment planning system, to model the effects of rounded MLC leaf ends. Measuring the DLG using the conventional sliding-slit technique has been shown to be produce questionable results for some volumetric modulated arc therapy (VMAT) treatments. This study therefore investigated the use of radiochromic film measurements to optimize the DLG specifically for the purpose of producing accurate VMAT plans using a flattening-filter-free (FFF) beam, for use in treating vertebral targets using a stereotactic (SABR, also known as SBRT) fractionation schedule. Four test treatments were planned using a VMAT technique, to deliver a prescription of 24 Gy in 3 fractions to four different spine SABR treatment sites. Measurements of the doses delivered by these treatments were acquired using an ionization chamber and radiographic film. These measurements were compared with the doses calculated by the treatment planning system using a range of DLG values, including a DLG identified using the conventional sliding-slit method (1.1 mm). An optimal DLG value was identified, as the value that produced the closest agreement between the planned and measured doses (1.9 mm). The accuracy of the dose calculations produced using the optimized DLG value was verified using additional radiochromic film measurements in a heterogeneous phantom. This study provided a specific initial DLG (1.9 mm) as well as a film-based optimization method, which may be used by radiotherapy centers when attempting to commission or improve an FFF VMAT-based SABR treatment programme.
16
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Stanley Benedict, Kamil M. Yenice, D Followill et al. · Medical Physics · 2010 · 2.2K citations · Full text
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
Evaluation of the gamma dose distribution comparison method
Daniel A. Low, James F. Dempsey · Medical Physics · 2003 · 752 citations
Brett Cox, Daniel E. Spratt, Michael Lovelock et al. · International Journal of Radiation Oncology*Biology*Physics · 2012 · 611 citations