A Comparison Between Electrical Capacitance Tomography and Displacement-Current Phase Tomography

Cagdas Gunes, Qussai M. Marashdeh, Fernando L. Teixeira

IEEE Sensors Journal · 2017 · 46 citations · 35 references

Concepts

Abstract

We compare electrical capacitance tomography (ECT) and displacement-current phase tomography (DCPT) results for non-invasive imaging of lossy media. ECT is based on mutual capacitance measurements between electrode pairs surrounding the region of interest (RoI), whereas DCPT is a relatively less mature sensing modality that utilizes the phase information inherent in the displacement current measured by such electrode pairs excited by time-harmonic voltages (in the electroquasistatic regime). DCPT and ECT can be implemented using basically the same hardware components and used alongside to provide complementary information for imaging purposes or separately to reconstruct the spatial distribution of the loss tangent or the permittivity within the RoI, respectively. We show that the (nonlinear) relationship between the measured phase in DCPT and the conductivity distribution in the RoI has a more extended linear range than the nonlinear relationship between the measured capacitances in ECT and the permittivity distribution in the RoI. Of note, DCPT does not require electrical contact with the RoI in contrast to electrical impedance tomography. To illustrate the potential of DCPT, we evaluate its performance using both numerical examples and experiment results.

References

35