Oxidative Neutralization of Mustard‐Gas Simulants in an On‐Board Flow Device with In‐Line NMR Monitoring

Baptiste Picard, Boris Gouilleux, Thomas Lebleu, Jacques Maddaluno, Isabelle Chataigner, Maël Penhoat, François‐Xavier Felpin, Patrick Giraudeau, Julien Legros

Angewandte Chemie International Edition · 2017 · 58 citations · 38 references

Concepts

Abstract

Abstract The fast and effective neutralization of the mustard‐gas simulant 2‐chloroethyl ethyl sulfide (CEES) using a simple and portable continuous flow device is reported. Neutralization takes place through a fully selective sulfoxidation by a stable source of hydrogen peroxide (alcoholic solution of urea–H 2 O 2 adduct/MeSO 3 H freshly prepared). The reaction progress can be monitored with an in‐line benchtop NMR spectrometer, allowing a real‐time adjustment of reaction conditions. Inherent features of millireactors, that is, perfect control of mixing, heat and reaction time, allowed the neutralization of 25 g of pure CEES within 46 minutes in a 21.5 mL millireactor ( t R =3.9 minutes). This device, which relies on affordable and nontoxic reagents, fits into a suitcase, and can be deployed by police/military forces directly on the attack site.

References

38