IEEE Sensors Journal · 2017 · 24 citations · 23 references
EngineeringBioengineeringBiomedical EngineeringBiomedical OpticsBiophotonicsBiosensorsMedical InstrumentationOptical DiagnosticsPoint-of-care Diagnostic DevicesAssessment Of Oxygen SaturationContinuous MonitoringOxygen Saturation MeasurementOxygen Saturation MonitoringPolarizationPulse OximetersPulse Oximetry
Blood oxygen saturation (SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) measurement is a routinely performed clinical procedure involved in the diagnosis of several critical diseases. However, the most commonly used SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> measuring device, known as oximeter, becomes unreliable in the absence of proper body contact. A non-contact, noninvasive, real-time device is desirable for accurate measurement and continuous monitoring of SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> . This paper presents a polarized imaging-based integrated solution for SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> measurement. The polarization filters are used to separate light components reflecting from deep and superficial layers of skin. The ratio of intensities of the two components is found to have a linear relationship with SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> levels. In contrast to the existing SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> measurement techniques, the proposed method uses a single light source. The experiments are performed with 15 human subjects (11 male and 4 female) using different wavelengths of light. A statistically significant relationship is observed between SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> and the intensity ratios for red light (correlation coefficient r = 0.6426 with p=0.001965 and mean error = 0.0626). The experiments are repeated using white light, and a similar relationship is observed (r = 0.5603 with p = 0.00947 and mean error = -0.9289). Furthermore, the Bland-Altman analysis shows that the results of the proposed method are consistent with the reference data. This suggests that a real-time integrated polarized imaging-based SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> measurement device can be developed based on the proposed method.
23
Algorithmic Principles of Remote PPG
Wenjin Wang, Albertus C. den Brinker, Sander Stuijk et al. · IEEE Transactions on Biomedical Engineering · 2016 · 1.2K citations · Full text