Journal of the Japan Institute of Metals and Materials · 1993 · 35 citations · 0 references
Natural SciencesMaterials EngineeringMaterials ScienceCeramic MaterialsMechanical Behavior Of MaterialsMetallurgyAlloy DesignAlloysImplant MaterialsMetalsBiomedical ImplantsCasting AlloysImplant Material MechanicsTensile StrengthTitanium AlloysTitanium Implant MaterialsTitanium MaterialsUltimate Tensile Strength
Titanium alloys for medical implants were casted using 5∼20 mass%Zr, 10∼20%Sn, 4∼8%Nb, 2∼4%Ta and 0∼0.2%Pd as alloying elements instead of using harmful Al and V.The alloys were forged in their α and α+β regions followed by annealing at 973 K for 7.2 ks. The annealed microstructures of the alloys consisted mainly of the acicular structure containing elongated β grains in the range from 10 to 30 vol%.The room temperature tensile strength of the alloys markedly increased with increasing Sn content, as compared with increasing than Zr content. As a result, the Ti-15%Sn-4%Nb-2%Ta-0.2%Pd alloy surpassed the Ti-6%Al-4%V extra low interstitial alloy for medical implants (ASTM F136-84 standard) in tensile strength as well as in elongation and reduction of area. The tensile strength was further improved by the additions of nitrogen and oxygen.