EngineeringEnvironmental EngineeringEnvironmental SciencesElectrochemistryWastewater TreatmentWater TreatmentElectrochemical ReactorsElectrochemical TreatmentIndustrial Wastewater TreatmentRedox ChemistryRedox ProcessesRedox ReactionsAnodic OxidationElectrochemical OxidationElectrochemical Oxidation ReactorsElectrochemical RemediationFenton ReactionOxidationOxidation ProcessesRemoval Efficiency
ABSTRACT The aim of this study was to investigate the removal efficiency of color and COD from industrial dyeing waste-water using paired electrochemical oxidation in a divided flow-by electrochemical reactor. The color and COD were removed by electrogenerated HOCl using a DSA (Ti/RuO 2 ) electrode in the anodic compartment, while in the cathodic compartment, the color and COD were removed by ·OH produced by combing the cathodically generated H 2 O 2 with Fe 2+ (Fenton’s reagent). Findings showed that the color was more easily removed than the COD. After passing 12,960 C through the cell, the removal efficiencies reached 98.2 % for color and 92.8 % for COD by anodic oxidation and 94.2 % for color and 78.5 % for COD by electro-Fenton oxidation. The color and COD removal efficiencies for anodic oxidation fell slightly with increasing solution pH and rose with increases in the applied current and the amount of added NaCl. In contrast, increasing the amount of added NaCl slightly lowered the removal efficiencies for electro-Fenton. The removal efficiencies rose with in-creasing applied current up to 0.9 A, and the optimal pH was 3.0 for electro-Fenton. The highest current efficien-cies achieved were 94.8 % for anodic oxidation and 75.5 % for electro-Fenton.