Endoscopy · 2017 · 17 citations · 34 references
MedicineClinical SciencesOncologyCancer ScreeningGastroenterologyGastrointestinal OncologyColorectal CancerGastrointestinal EndoscopyGastrointestinal ImagingColonoscopy ScreeningColorectal AdenomasColorectal Cancer DiagnosisColorectal Cancer ScreeningReference Method ComparisonSmall Adenoma Detection
Abstract Background and aims Colonoscopy is currently the reference method to detect colorectal neoplasia, yet some adenomas remain undetected. The water infusion technique and dying with indigo carmine has shown interesting results for reducing this miss rate. The aim of this study was to compare the adenoma detection rate (adenoma and adenocarcinoma; ADR) and the mean number of adenomas per patient (MAP) for blue-water infusion colonoscopy (BWIC) versus standard colonoscopy. Methods We performed a multicenter, randomized controlled trial in eight units, including patients with a validated indication for colonoscopy (symptoms, familial or personal history, fecal occult blood test positive). Consenting patients were randomized 1:1 to BWIC or standard colonoscopy. All colonoscopies were performed by experienced colonoscopists. All colonoscopy quality indicators were prospectively recorded. Results Among the 1065 patients included, colonoscopies were performed completely for 983 patients (514 men; mean age 59.1). The ADR was not significantly different between the groups; 40.4 % in the BWIC group versus 37.5 % in the standard colonoscopy group (odds ratio [OR] 1.13; 95 % confidence interval [CI] 0.87 – 1.48; P = 0.35). MAP was significantly greater in the BWIC group (0.79) than in the standard colonoscopy group (0.64; P = 0.005). For advanced adenomas, the results were 50 (10.2 %) and 36 (7.3 %), respectively (P = 0.10). The cecal intubation rate was not different but the time to cecal intubation was significantly longer in BWIC group (9.9 versus 6.2 minutes; P < 0.001). Conclusion Despite the higher MAP with BWIC, the routine use of BWIC does not translate to a higher ADR. Whether increased detection ultimately results in a lower rate of interval carcinoma is not yet known. Clinical trials registration: EudraCT 2012-A00548 – 35; NCT01937429.
34
Prevention of Colorectal Cancer by Colonoscopic Polypectomy
Sidney J. Winawer, Ann G. Zauber, May Nah Ho et al. · New England Journal of Medicine · 1993 · 4.6K citations · Full text
Adenoma Detection Rate and Risk of Colorectal Cancer and Death
Douglas A. Corley, Christopher D. Jensen, Amy R. Marks et al. · New England Journal of Medicine · 2014 · 2.2K citations · Full text
The Vienna classification of gastrointestinal epithelial neoplasia
Ronald J. Schlemper · Gut · 2000 · 2.1K citations · Full text
Quality Indicators for Colonoscopy and the Risk of Interval Cancer
Michał F. Kamiński, Ewa Kraszewska, Marcin Polkowski et al. · New England Journal of Medicine · 2010 · 2K citations
Medicine, Biostatistics, Oncology +14
Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
DK Rex, CS Cutler, GT Lemmel et al. · Gastroenterology · 1997 · 1.6K citations · Full text