Physical Therapy · 2017 · 54 citations · 20 references
MedicineGeriatric MedicinePhysical MedicineExercise TestingGeriatric AssessmentPhysical TherapyFunctional Assessment In Older AdultsGait AnalysisGait AssessmentLower Extremity Function AssessmentPhysical Performance AssessmentPower TestingMinimal Detectable ChangeStair Climbing AbilityStair Climbing KineticsStair Climbing Performance
BACKGROUND: Stair climb power is an important clinical measure of lower-extremity power. The stair climb power test (SCPT) was validated by requiring individuals to climb a full flight of stairs. A 4-step SCPT (4SCPT) would be more clinically feasible and easier to perform, yet its reliability and validity are unknown. OBJECTIVE: To evaluate reliability, validity, and minimal detectable change of 4SCPT among community-dwelling older adults. DESIGN: This study is a cross-sectional analysis of baseline data from a clinical trial. METHODS: Fifty older adults ≥65 years of age, at risk for mobility decline, consented to participate in this ancillary study. Test-retest reliability was derived from 2 measurements within each participant measured by a single assessor. Pearson correlation analyses among leg power measures (4SCPT, SCPT, single leg press power at 40% and 70% of the 1-repetition maximum [SLP40, SLP70]) were performed. Separate multivariate linear regressions were conducted evaluating the associations between each leg power measure and 2 mobility outcomes, the Short Physical Performance Battery (SPPB) and habitual gait speed (HGS). Minimal detectable change was based on a 90% confidence interval (MDC 90 ). RESULTS: The 4SCPT had excellent test-retest reliability (ICC(2,1) = 0.951), and strong correlation with SCPT, SLP40, and SLP70 ( r = 0.85-0.96). The 4SCPT explained a greater amount of variance in the SPPB (R 2 = 0.31) than other leg power measurements (R 2 = 0.23-0.25). The 4SCPT (R 2 = 0.41) and SCPT (R 2 = 0.42) described equivalent amounts of variance in HGS, and greater than that with SLP40 (R 2 = 0.28) and SLP70 (R 2 = 0.30). The MDC 90 for 4SCPT was 44.0 watts. LIMITATIONS: This was a cross-sectional analysis within a small, nonrepresentative sample. Interrater reliability was not evaluated. CONCLUSIONS: The 4SCPT shows scientific promise as a valid and reliable leg power measurement among community-dwelling older adults.
20
Psychophysical bases of perceived exertion
Gunnar Borg · Medicine & Science in Sports & Exercise · 1982 · 16.4K citations
Jack M. Guralnik, E. M. Simonsick, Luigi Ferrucci et al. · Journal of Gerontology · 1994 · 9.7K citations
Jack M. Guralnik, Luigi Ferrucci, Carl F. Pieper et al. · The Journals of Gerontology Series A · 2000 · 2.9K citations · Full text
Leg extensor power and functional performance in very old men and women
E. J. Bassey, M. A. Fiatarone, Evelyn F. O’Neill et al. · Clinical Science · 1992 · 942 citations
Strength, Power and Related Functional Ability of Healthy People Aged 65–89 Years
Dawn A. Skelton, Carolyn Greig, Janet Davies et al. · Age and Ageing · 1994 · 940 citations