MedicineCardiologySurgeryCardiothoracic SurgeryCritical Care CardiologyHemodynamic ManagementBlood Pressure ManagementCardiopulmonary BypassCardiovascular MonitoringHemodynamic SupportHemodynamicsRadial Artery AccessArterial Blood Pressure MeasurementBlood PressureBlood Pressure MonitoringInvasive Arterial Blood Pressure MonitoringRadial Artery CannulationSystolic Blood PressureWeaning From BypassWeaning From Cardiopulmonary Bypass
Objective: To determine the accuracy of peripheral (radial) arterial access as compared to central (femoral) arterial access for measurement of invasive blood pressure (IBP) in critically ill patients after cardiopulmonary bypass.Methods: Sixty patients (60) who required high inotropic/vasopressor support on weaning from cardio-pulmonary bypass and weaned off in 2nd attempt were included in this study. The duration of this study was from June 2015 to August 2016. Radial and femoral arterial access was achieved in all patients for simultaneous measurement of blood pressure. Arterial pressures were noted after 5, 15 and 30 minutes of weaning from cardiopulmonary bypass for both radial and femoral artery simultaneously.Results: Mean age of study patients was 56.48±11.17 years. 85% patients were male. There was significant difference in systolic blood pressure, diastolic blood pressure and mean arterial pressures between the radial artery and femoral artery cannulation. Mean arterial pressures were significantly high in femoral artery as compared to the radial artery. The mean arterial pressures after five minutes of weaning using central access were 76.28±10.21 mmHg versus 64.15±6.76 mmHg in peripheral arterial access (p-value <0.001). Similarly we also found significant difference in mean arterial pressures after 15 minutes of weaning from cardiopulmonary bypass 78.70±10.12 mmHg in central access versus 72.03±6.76 mmHg using peripheral arterial access (p-value <0.001). The difference in arterial pressures were less marked as compared to the previous differences after 30 minutes of weaning from cardiopulmonary bypass as compared to the earlier readings (p-value 0.001).Conclusion: Peripheral arterial pressures are unreliable in critically ill patients after cardiopulmonary bypass receiving high dose of inotropic drugs. Central arterial access should be used in these patients to get accurate estimates of patients’ blood pressure in early periods after cardiopulmonary bypass.doi: https://doi.org/10.12669/pjms.332.12220How to cite this:Ahmad RA, Ahmad S, Naveed A, Baig MAR. Peripheral arterial blood pressure versus central arterial blood pressure monitoring in critically ill patients after Cardio-pulmonary Bypass. Pak J Med Sci. 2017;33(2):310-314. doi: https://doi.org/10.12669/pjms.332.12220This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
25
R. Phillip Dellinger, Mitchell M. Levy, Andrew Rhodes et al. · Critical Care Medicine · 2013 · 9.7K citations
Veterinary Medicine, Infectious Diseases, Internal Medicine +9
Hemodynamic monitoring in shock and implications for management
Massimo Antonelli, Mitchell M. Levy, Peter Andrews et al. · Intensive Care Medicine · 2007 · 468 citations · Full text
Does Radial Artery Pressure Accurately Reflect Aortic Pressure?
Alfredo L. Pauca, Stephen L. Wallenhaupt, Neal D. Kon et al. · CHEST Journal · 1992 · 342 citations
Medicine, Cardiology, Surgery +10
Pressure Wave Transmission along the Human Aorta
Michael F. O’Rourke, James V. Blazek, Charles L. Morreels et al. · Circulation Research · 1968 · 242 citations · Full text
Medicine, Cardiology, Acoustics +15