Indoor Air · 2017 · 153 citations · 28 references
ArchitectureArchitectural EngineeringBuilding ScienceHvac SystemsIndoor Environmental QualityVentilationAerosol ScienceAir QualityAirflow DistributionAirflow SimulationParticulate MatterVentilation SystemsAerosol Particle Size DistributionAerosol Size DistributionConcentration DistributionIndoor Air Quality MeasurementNitrous OxideOccupant Exposure AssessmentRoom Air DistributionTracer Gas Measurement
The study examined how ventilation rate, free convection from a thermal manikin, and the presence of objects affect indoor tracer gas and particle distribution. The authors measured aerosol and tracer gas concentrations in a mixing‑ventilated test room across three layouts—empty, office with a manikin, and single‑bed hospital—using monodisperse particles (0.07, 0.7, 3.5 µm) and nitrous oxide, sampling bulk air, breathing zone, and exhaust. Tracer gas reliably predicted exposure to all particle sizes in the breathing zone, and neither changes in ventilation rate nor increased room surface area altered the similarity between tracer gas and larger particle dispersion.
The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas.
28