Neuron-Specific Enolase Predicts Poor Outcome After Cardiac Arrest and Targeted Temperature Management: A Multicenter Study on 1,053 Patients
118
Citations
22
References
2017
Year
High neuron-specific enolase serum concentrations reliably predicted poor outcome at ICU discharge. Prediction accuracy differed and was better for out-of-hospital cardiac arrest than for in-hospital cardiac arrest patients. Our "in-the-field" data indicate 90 μg/L as a threshold associated with almost no false positives at acceptable sensitivity. Confounders of neuron-specific enolase elevation should be actively considered: neuron-specific enolase-producing tumors, acute brain diseases, and hemolysis. We strongly recommend routine hemolysis quantification. Neuron-specific enolase serum concentrations less than or equal to 17 μg/L argue against hypoxic-ischemic encephalopathy incompatible with reawakening.