BioMed Research International · 2017 · 12 citations · 13 references
Veterinary MedicineOral RadiologyRadiologyDiagnostic ImagingDiagnostic RadiologyDigital ImagingDetector TechnologyImage Quality AssessmentIntraoral RadiographyMedical ImagingRadiation Imaging DetectorsRadiographic ImagingContrast RatioDetectorsDigital Radiography DetectorsImage Contrast EffectsImage Contrast EvaluationPhosphor Plate ImagingPhotostimulable Phosphor ImagingSignal-to-noise Ratio
The purpose is to evaluate the performance of current intraoral digital detectors in detail using a precise phantom and new method. Two aluminum step wedges in 0.5 mm steps were exposed by two photostimulable phosphor plate (PSP) systems—one with automatic exposure compensation (AEC) and the other without AEC—and a CCD sensor. Images were obtained with 3 doses at 60 kV. The effect of metallic material also was evaluated. The contrast-to-noise ratio (CNR) for thinner steps and the low contrast value (LCV) for thicker steps were obtained. The CCD system was the best under all conditions (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mi>P</mml:mi><mml:mo><</mml:mo><mml:mn fontstyle="italic">0.001</mml:mn></mml:math>), although the Gray value was sensitive to the dose, and the Gray value-dose relation varied greatly. The PSP system with AEC was superior to that without AEC for the LCV (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mi>P</mml:mi><mml:mo><</mml:mo><mml:mn fontstyle="italic">0.001</mml:mn></mml:math>) but was inferior to it regarding the CNR (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mi>P</mml:mi><mml:mo><</mml:mo><mml:mn fontstyle="italic">0.001</mml:mn></mml:math>). CNR and LCV in the PSP system without AEC were not affected by the metallic plate. Intraoral digital imaging systems should be chosen according to their diagnostic purpose. PSP system with AEC may be the best for detecting molar proximal caries, whereas the PSP system without AEC may be better for evaluating small bone regeneration in periodontal disease. The CCD system provided the best performance.
13
Computed radiography utilizing scanning laser stimulated luminescence.
Mitumasa Sonoda, Masao Takano, Junji Miyahara et al. · Radiology · 1983 · 865 citations
Presentation and physical evaluation of RadioVisioGraphy
Francis Mouyen, Christoph Benz, E Sonnabend et al. · Oral Surgery Oral Medicine Oral Pathology · 1989 · 234 citations
Kıvanç Kamburoğlu, Igor Tsesis, Anda Kfir et al. · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · 2008 · 43 citations
Dentistry, Oral Radiology, Radiology +16