Translational and Clinical Pharmacology · 2017 · 13 citations · 28 references
This study was performed to evaluate the use of vibrating microneedles for the transdermal delivery of vitamin C. The microneedles were designed to vibrate at three levels of intensity. <i>In vitro</i> permeation by vitamin C was evaluated according to the specific conditions such as vibration intensity (levels 1, 2 and 3), application time (1, 3, 5, 7 and 10 min), and application power (500, 700 and 1,000 g). The highest permeation of vitamin C was observed at level 3 of vibration intensity, 5 min of application, and 1,000 g of application power. Vitamin C gel showed no cytotoxic effect against Pam212 cells or skin irritation effects. A pharmacokinetic study of the gel in rats was conducted under optimized conditions. The AUC<sub>0</sub>-<sub>∞</sub> and C<sub>max</sub> increased 1.35-fold and 1.44-fold, respectively, compared with those after vitamin C gel without application with vibrating microneedles. The present study suggests that vibrating microneedles can be used to facilitate the skin permeability of vitamin C under optimal conditions.
28
Dissolving microneedles for transdermal drug delivery
Jeong Woo Lee, Jung‐Hwan Park, Mark R. Prausnitz · Biomaterials · 2008 · 914 citations · Full text