Comparison of the Marginal Fit of Cobalt-Chromium Metal-Ceramic Crowns Fabricated by CAD/CAM Techniques and Conventional Methods at Three Production Stages

Francisco Real‐Voltas, Elisabeth Romano-Cardozo, Òscar Figueras-Álvarez, M Barbera, Josep Cabratosa‐Termes

The International Journal of Prosthodontics · 2017 · 17 citations · 4 references

Concepts

Abstract

Francisco Real-Voltas, MD, PhD/Elisabeth Romano-Cardozo, MD, PhD/Oscar Figueras-Alvarez, MD, PhD/Magi Brufau-de Barbera, MD, PhD/Josep Cabratosa-Termes, MD, PhD: Purpose: The aim of this study was to compare the marginal fit of cobalt-chromium crowns fabricated using conventional casts and computer-aided design/computer-assisted manufacturing (CAD/CAM) techniques at three stages of production: metal coping, after porcelain firing, and after cementation. Materials and Methods: A total of 80 metal-ceramic crowns were fabricated using four different techniques: lost wax casting, milling, laser sintering, and milling of a presintered metal block. Marginal fit was measured at each manufacturing stage. Results: The porcelain firing stage improved marginal fit. CAD/CAM techniques resulted in better marginal fit than did conventional casting techniques at all manufacturing stages. Conclusion: CAD/CAM techniques improve marginal fit.

References

4