Capacitor impedance estimation utilizing dc‐link voltage oscillations in single phase inverter

Abhinav Arya, Md Waseem Ahmad, Nikunj Agarwal, Sandeep Anand

IET Power Electronics · 2017 · 23 citations · 24 references

Concepts

Abstract

Grid tied single‐phase solar inverters offer less operational life when compared with the Photovoltaic (PV) panels due to the use of aluminium electrolytic capacitor (AEC). With time, AEC degrades, resulting in an increase in ripple voltage on PV panel. This would reduce the power extraction efficiency of the system, thereby a loss of revenue. This study proposes a simple and cost‐efficient online technique for monitoring the health of AECs. The proposed technique suggests evaluating the AEC impedance at twice the grid frequency. Sampling of PV voltage, PV current and inductor current is required to determine the second harmonic impedance of AEC. These voltage and current sensors are present in commercially available solar PV inverters for their control operation. The proposed technique could be extended to other single‐phase inverter applications provided that voltage and current sensors are available. Suitable mathematical model of the technique is derived to determine the effect of sampling instant on the accuracy of the results. Criteria for the replacement of capacitor based on impedance monitoring is defined. For validation of the proposed technique, detailed simulation studies are carried out for a single‐phase PV system. The technique is verified experimentally on a scaled down solar PV inverter prototype.

References

24