World Journal of Orthopedics · 2017 · 27 citations · 23 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopedicsProstheticsAnkle ArthroplastyAnkle OrthopedicsAnkle SurgeryLower-limb ProstheticsProsthetic ManagementAnkle Varus DeformityDirect Anterior ApproachTalar ComponentTalus Anatomy
Regauer M et al . Internally braced total talus prosthesis N. Correct implantation of the prosthesis was technically possible via an anterior approach to the ankle and using standard instruments. Malleolar osteotomies were not required. Maximum ankle dorsiflexion and plantarflexion were measured as 22-0-28 degrees. Maximum anterior displacement of the talus was 6 mm, maximum varus tilt 3 degrees and maximum valgus tilt 2 degrees. Application of an internally braced prosthesis for total talus replacement in humans is technically feasible and might be a reasonable procedure in carefully selected cases with no better alternatives left.
23