The Laryngoscope · 2017 · 171 citations · 24 references
Health ProfessionsAudiologyOtolaryngologyCochlear ImplantsHearing AssessmentOtologyAdult Cochlear ImplantsCochlear ImplantationElectrode PlacementResidual Hearing PreservationSpeech Perception OutcomesSurgical ImplantationCochlear Electrode Array PositioningElectrode Array InsertionIntracochlear Electrode Array PositioningLateral Wall Electrode ArraysLateral Wall ElectrodesPost-implantation Speech PerceptionPreoperative Hearing AssessmentScala Tympani Insertion
OBJECTIVES: 1) Examine angular insertion depths (AID) and scalar location of Med-El (GmbH Innsbruck, Austria) electrodes; and 2) determine the relationship between AID and audiologic outcomes controlling for scalar position. STUDY DESIGN: Retrospective review. METHODS: Postlingually deafened adults undergoing cochlear implantation with Flex 24, Flex 28, and Standard electrode arrays (Med-El) were identified. Patients with preoperative and postoperative computed tomography scans were included so that electrode location and AID could be determined. Outcome measures were 1) speech perception in the cochlear implant (CI)-only condition, and 2) short-term hearing preservation. RESULTS: Forty-eight implants were included; all electrodes (48 of 48) were positioned entirely within the scala tympani. The median AID was 408° (interquartile [IQ] range 373°-449°) for Flex 24, 575° (IQ range 465°-584°) for Flex 28, and 584° (IQ range 368°-643°) for Standard electrodes (Med-El). The mean postoperative CNC score was 43.7% ± 21.9. A positive correlation was observed between greater AID and better CNC performance (r = 0.48, P < 0.001). Excluding patients with postoperative residual hearing, a strong correlation between AID and CNC persisted (r = 0.57, P < 0.001). In patients with preoperative residual hearing, mean low-frequency pure-tone average (PTA) shift was 27 dB ± 14. A correlation between AID and low-frequency PTA shift at activation was noted (r = 0.41, P = 0.04). CONCLUSION: Favorable rates of scala tympani insertion (100%) were observed. In the CI-only condition, a direct correlation between greater AID and CNC score was noted regardless of postoperative hearing status. Deeper insertions were, however, associated with worse short-term hearing preservation. When patients without postoperative residual hearing were analyzed independently, the relationship between greater insertion depth and better performance was strengthened. LEVEL OF EVIDENCE: 4. Laryngoscope, 127:2352-2357, 2017.
24
Factors Affecting Open-Set Word Recognition in Adults With Cochlear Implants
Laura K. Holden, Charles C. Finley, Jill B. Firszt et al. · Ear and Hearing · 2013 · 964 citations
Revised CNC Lists for Auditory Tests
Gordon E. Peterson, Ilse Lehiste · Journal of Speech and Hearing Disorders · 1962 · 802 citations
Medicine, Audiology, Otolaryngology +14