Journal of Applied Clinical Medical Physics · 2017 · 97 citations · 16 references
MedicineMaterials ScienceRadiation OncologyRadiation DosimetryRadiation ProtectionRadiation SafetyAbsorbed DoseExternal Beam RadiotherapyMonte Carlo DosimetryPhantom DosimetryRadiation Dose MeasurementRadiation TherapyDose Distribution CalculationsDose Perturbation AnalysisExternal Beam Dose DistributionHigh-energy Photon Beam DosimetryMonte Carlo Dose SimulationStainless Steel ImplantsTitanium MaterialsWater Phantom Measurements
Radiation therapy, in conjunction with surgical implant fixation, is a common combined treatment in cases of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced Polyetheretherketone (CFR-PEEK) material has been recently introduced for production of intramedullary nails and plates. The purpose of this work was to investigate the perturbation effects of the new CFR-PEEK screws on radiotherapy dose distributions and to evaluate these effects in comparison with traditional titanium screws. The investigation was performed by means of Monte Carlo (MC) simulations for a 6 MV photon beam. The project consisted of two main stages. First, a comparison of measured and MC calculated doses was performed to verify the validity of the MC simulation results for different materials. For this purpose, stainless steel, titanium, and CFR-PEEK plates of various thicknesses were used for attenuation and backscatter measurements in a solid water phantom. For the same setup, MC dose calculations were performed. Next, MC dose calculations for titanium, CFR-PEEK screws, and CFR-PEEK screws with ultrathin titanium coating were performed. For the plates, the results of our MC calculations for all materials were found to be in good agreement with the measurements. This indicates that the MC model can be used for calculation of dose perturbation effects caused by the screws. For the CFR-PEEK screws, the maximum dose perturbation was less than 5%, compared to more than 30% perturbation for the titanium screws. Ultrathin titanium coating had a negligible effect on the dose distribution. CFR-PEEK implants have good prospects for use in radiotherapy because of minimal dose alteration and the potential for more accurate treatment planning. This could favorably influence treatment efficiency and decrease possible over- and underdose of adjacent tissues. The use of such implants has potential clinical advantages in the treatment of bone metastases.
16
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
D. W. O. Rogers, Bruce Faddegon, G Ding et al. · Medical Physics · 1995 · 1.4K citations
Polyetheretherketone as a biomaterial for spinal applications
Jeffrey M. Toth, Mei Wang, Bradley T. Estes et al. · Biomaterials · 2005 · 556 citations · Full text
B. R. B. Walters, I. Kawrakow · NPARC · 2016 · 256 citations
Chester S. Reft, Rodica Alecu, Indra J. Das et al. · Medical Physics · 2003 · 249 citations · Full text