Acta Radiologica · 2016 · 20 citations · 11 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAtrial FibrillationCardiac ArrhythmiasCardiac ImagingCardiovascular ImagingMagnetic Resonance ImagingMedical ImagingArrhythmia DetectionArrhythmia DiagnosisAtrial Fibrillation AssessmentAtrial Fibrillation ImagingCardiac Cine ImagingCine Magnetic Resonance ImagingQuantitative Cardiac ImagingVolumetric Data Acquisition
Background Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. Purpose To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification in atrial fibrillation. Material and Methods On a 1.5T MR system left ventricular short-axis stacks were acquired of the SPARSE sequence and of a "reference" steady-state free precession (SSFP) sequence with arrhythmia rejection in 20 patients with atrial fibrillation. Two radiologists independently rated arrhythmia-caused artifact severity in both sequences using a 4-point scale. Coefficients of variation of myocardial signal intensity for both sequences were acquired. Volumetry was performed twice by one reader and once by another reader. Correlation between artifact severity and employed sequence was analyzed by modified Fisher's exact test. Coefficients of variation and volumetric data were compared by paired t-test and intraclass correlation. Results Median arrhythmia-caused artifact severity was 2 in both readers for SSFP and 0 (reader 1)/1 (reader 2) for SPARSE, being significantly lower in SPARSE ( P < 0.001). Mean coefficient of variance was significantly smaller in SPARSE (0.11 ± 0.04) compared to SSFP (0.22 ± 0.13, P = 0.003), which was interpreted as a hint for fewer artifacts in SPARSE. Only a small difference of 9 ± 15 mL was seen for end-systolic volume ( P = 0.019) between sequences, otherwise no significant difference was detected (end-diastolic volume, P = 0.200; stroke volume, P = 0.554; ejection fraction, P = 0.136; myocardial mass, P = 0.353). Intraclass correlation between sequences was good to excellent (range, 0.80-0.97). Conclusion Real-time MRI with SPARSE data sampling is promising in atrial fibrillation because it reduces arrhythmia-caused artifacts.
11
Highly accelerated real‐time cardiac cine MRI using <i>k</i>–<i>t</i> SPARSE‐SENSE
Li Feng, Monvadi B. Srichai, Ruth Lim et al. · Magnetic Resonance in Medicine · 2012 · 236 citations
Medicine, Cardiology, Radiology +17
Cyrus R. Mehta, Nitin R. Patel · ACM Transactions on Mathematical Software · 1986 · 206 citations · Full text