Journal of Ophthalmology · 2017 · 48 citations · 18 references
MedicineOphthalmologyVision ScienceClinical OptometryOcular ImagingOphthalmic SurgeryCorneal ImagingCorneal OpticsCorneal TomographyCorneal TopographyOcular BiometryBland-altman PlotCentral Corneal Thickness MeasurementCorneal DiagnosticsCorneal Thickness AssessmentCorneal Topography AssessmentIntraclass CorrelationOcular BiometricsPentacam Imaging
Background. To estimate repeatability and comparability of central corneal thickness (CCT) and keratometry measurements obtained by four different devices in healthy eyes. Methods. Fifty-five healthy eyes from 55 volunteers were enrolled in this study. CCT (IOLMaster 700, Pentacam HR, and Cirrus HD-OCT) and keratometry readings (IOLMaster 700, Pentacam HR, and iDesign) were measured. For statistical analysis, the corneal spherocylinder was converted into power vectors (J0, J45). Repeatability was assessed by intraclass correlation coefficient (ICC). Agreement of measurements between the devices was evaluated by the Bland-Altman method. Results. The analysis of repeatability of CCT data of IOLMaster 700, Pentacam HR, and Cirrus HD-OCT showed high ICCs (range 0.995 to 0.999). The comparison of CCT measurements revealed statistically significant differences between Pentacam HR versus IOLMaster 700 (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.0001</mml:mn></mml:math>) and Pentacam HR versus Cirrus HD-OCT (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.0001</mml:mn></mml:math>), respectively. There was no difference in CCT measurements between IOLMaster 700 and Cirrus HD-OCT (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn>0.519</mml:mn></mml:math>). The repeatability of keratometry readings (J0 and J45) of IOLMaster 700, Pentacam HR, and iDesign was also high with ICCs ranging from 0.974 to 0.999. The Pentacam HR revealed significantly higher J0 in comparison to IOLMaster 700 (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M4"><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn>0.009</mml:mn></mml:math>) and iDesign (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M5"><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn>0.041</mml:mn></mml:math>); however, no significant difference was between IOLMaster 700 and iDesign (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M6"><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn>0.426</mml:mn></mml:math>). Comparison of J45 showed no significant difference between IOLMaster 700, Pentacam HR, and iDesign. These results were in accordance with Bland-Altman plots. Conclusion. In clinical practice, the devices analyzed should not be used interchangeably due to low agreement regarding CCT as well as keratometry readings.
18
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
Yaniv Barkana, Yariv Gerber, Uri Elbaz et al. · Journal of Cataract & Refractive Surgery · 2005 · 297 citations
The Repeatability of Corneal Thickness Measures
Matthew M. Marsich, Mark A. Bullimore · Cornea · 2000 · 295 citations