Procedia Engineering · 2017 · 21 citations · 3 references
EngineeringArchitectural EngineeringAcousticsMetrologyUncertainty QuantificationAcoustic MeasurementMeasurement UncertaintyNoiseNoise MeasurementNoise PollutionNoise AssessmentNoise Measurement UncertaintyRoad Noise MeasurementSound Pressure LevelSound Pressure Level MeasurementTraffic Noise AssessmentType A UncertaintyUrban Noise Assessment
This paper presents measurement results recorded by noise and traffic volume monitoring station located in Krakowska Street, Kielce. Poland. The measurements were performed in the period from January to December 2013, twenty-four hours a day and with a sampling time of 1 minute. The results were subjected to statistical analysis. A type A uncertainty was evaluated. A new parameter COVL Aeq was proposed for variability assessment of the equivalent sound pressure level.
3
Analysis of the Accuracy of Uncertainty Noise Measurement
Bartosz Przysucha, W. Batko, Agata Szeląg · Archives of Acoustics · 2015 · 12 citations · Full text
Natural Sciences, Physics, Acoustics +15