BMC Anesthesiology · 2017 · 15 citations · 11 references
MedicineAnesthesiologySurgeryAnesthesiaLaryngologyPulmonologyAirway AssessmentAirway ManagementAirway ObstructionEndotracheal IntubationDifficult Airway AssessmentEndotracheal Intubation TimingFeasibility Study DesignIntubation Success RatesIntubation Training Simulators
BACKGROUND: Videolaryngoscopy has become increasingly attractive for the routine management of the difficult airway. Glidescope® is well studied in the literature while imago V-Blade® is a recent videolaryngoscope. This is a feasibility study with 1:1 case-control sequential allocation comparing Imago V-Blade ® and Glidescope® in predicted difficult airway settings. METHODS: Two senior anesthesiologists with no clinical experience in video assisted intubation but previously trained in a simulated scenario, performed the endotracheal intubations with Imago V-Blade® and Glidescope®. A third experienced anesthesiologist supervised the procedures. Forty-two patients, 21 for each group, with the presence of predicted difficult airway according to the Italian guideline were included. The primary end point is the feasibility of intubation. The secondary end-points are the success to intubate in the first attempt, the intubation time, the Cormack and Lehane score view, the comparison of the intubation difficulty scale (IDS) score and the need for maneuvers to aid the endotracheal intubation comparing Imago V-Blade® and Glidescope®. RESULTS: The intubation was achieved in 100% of cases in both groups. No differences were found in the first-attempt success rate (p = 0.383), intubation time (p = 0.280), Cormack and Lehane score view (p = 0.799) and IDS score (p = 0.252). Statistical differences were found in external laryngeal pressure (p = 0.005), advancement of the blade (p = 0.024) and use of increasing lifting force (p = 0.048). CONCLUSIONS: This feasibility study showed that the intubation with the newly introduced Imago V-Blade® is feasible. Further randomized and/or non-inferiority trials are needed to evaluate the benefit of Imago V-Blade® in this procedure. TRIAL REGISTRATION: Clinicaltrials.gov NCT02897518 . Retrospectively registered 25 August 2016.
11
The Intubation Difficulty Scale (IDS)
Frédéric Adnet, Stephen W. Borron, S.X. Racine et al. · Anesthesiology · 1997 · 709 citations · Full text
Laryngoscopy via Macintosh Blade versus GlideScope
Parichehr Nouruzi-Sedeh, M. Schumann, Harald Groeben · Anesthesiology · 2008 · 242 citations
Recommendations for airway control and difficult airway management.
Flavia Petrini, Antonio Accorsi, Erica Adrario et al. · PubMed · 2005 · 208 citations
Medicine, Clinical Sciences, Surgery +12