Acta Radiologica · 2017 · 19 citations · 18 references
Veterinary MedicineRadiologySurgeryDiagnostic ImagingUltrasonographyUltrasoundAbdominal UltrasonographyComputed TomographyDiagnostic UltrasonographyImage FusionImage RegistrationMedical ImagingComputed Tomography Image FusionFocal Liver LesionsImage Data FusionMultimodal Image FusionRadiofrequency-assisted BiopsyRegistration Error AnalysisUltrasonography Of The LiverUltrasound Image Fusion
Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.
18
Multiple view geometry in computer vision
H. Opower · Optics and Lasers in Engineering · 2002 · 3K citations
Adaptive Thresholding using the Integral Image
Derek Bradley, Gerhard Roth · Journal of Graphics Tools · 2007 · 1.4K citations
Ray casting for modeling solids
Scott D Roth · Computer Graphics and Image Processing · 1982 · 606 citations