Photodiagnosis and Photodynamic Therapy · 2017 · 53 citations · 35 references
MedicineNeurological SurgeryOncologyBiomedical ImagingDiagnostic ImagingNeuro-oncologyCancer DetectionFluorescence ImagingFluorescence MicroscopyFluorescence SpectroscopyTumor DetectionTumor ImagingAutofluorescenceFluorescence Imaging ProbesFluorescence ProbesFluorescence QuantificationFluorescence-guided SurgeryHistopathological Image AnalysisIntraoperative Imaging ProbesTissue Autofluorescence
BACKGROUND: Visualization of the tumor is crucial for differentiating malignant tissue from healthy brain during surgery, especially in the tumor marginal zone. The aim of the study was to introduce a fluorescence spectroscopy-based hand-held probe (HHF-probe) for tumor identification in combination with the fluorescence guided resection surgical microscope (FGR-microscope), and evaluate them in terms of diagnostic performance and practical aspects of fluorescence detection. MATERIAL AND METHODS: Eighteen operations were performed on 16 patients with suspected high-grade glioma. The HHF-probe and the FGR-microscope were used for detection of protoporphyrin (PpIX) fluorescence induced by 5-aminolevulinic acid (5-ALA) and evaluated against histopathological analysis and visual grading done through the FGR-microscope by the surgeon. A ratio of PpIX fluorescence intensity to the autofluorescence intensity (fluorescence ratio) was used to quantify the spectra detected by the probe. RESULTS: Fluorescence ratio medians (range 0 - 40) measured by the probe were related to the intensity of the fluorescence in the FGR-microscope, categorized as "none" (0.3, n=131), "weak" (1.6, n=34) and "strong" (5.4, n=28). Of 131 "none" points in the FGR-microscope, 88 (67%) exhibited fluorescence with the HHF-probe. For the tumor marginal zone, the area under the receiver operator characteristics (ROC) curve was 0.49 for the FGR-microscope and 0.65 for the HHF-probe. CONCLUSIONS: The probe was integrated in the established routine of tumor resection using the FGR-microscope. The HHF-probe was superior to the FGR-microscope in sensitivity; it detected tumor remnants after debulking under the FGR-microscope. The combination of the HHF-probe and the FGR-microscope was beneficial especially in the tumor marginal zone.
35
An extent of resection threshold for newly diagnosed glioblastomas
Nader Sanai, Mei‐Yin C. Polley, Michael W. McDermott et al. · Journal of neurosurgery · 2011 · 1.6K citations
Medicine, Neurosurgery, Surgery +17
EXTENT OF RESECTION AND SURVIVAL IN GLIOBLASTOMA MULTIFORME
Walter Stummer, H. J. Reulen, Thomas R. Meinel et al. · Neurosurgery · 2008 · 1K citations