Real-time near-infrared fluorescence imaging using cRGD-ZW800-1 for intraoperative visualization of multiple cancer types

Henricus J.M. Handgraaf, Martin C. Boonstra, Hendrica A.J.M. Prevoo, Joeri Kuil, Mark W. Bordo, Leonora S. F. Boogerd, Babs G. Sibinga Mulder, Cornelis F.M. Sier, Maaike L. Vinkenburg-van Slooten, A. Rob P.M. Valentijn,

Oncotarget · 2017 · 72 citations · 30 references

DOIFull text

Open access

Concepts

Abstract

// Henricus J.M. Handgraaf 1, * , Martin C. Boonstra 1, * , Hendrica A.J.M. Prevoo 1 , Joeri Kuil 2 , Mark W. Bordo 3 , Leonora S.F. Boogerd 1 , Babs G. Sibinga Mulder 1 , Cornelis F.M. Sier 1 , Maaike L. Vinkenburg-van Slooten 1 , A. Rob P.M. Valentijn 2 , Jacobus Burggraaf 4, 5 , Cornelis J.H. van de Velde 1 , John V. Frangioni 3, 6, 7 , Alexander L. Vahrmeijer 1 1 Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands 2 Department of Clinical Pharmacy and Toxicology, Leiden University Medical Center, Leiden, The Netherlands 3 Curadel, LLC, Marlborough, MA, U.S.A 4 Centre for Human Drug Research, Leiden, The Netherlands 5 Leiden Academic Center for Drug Research, Leiden University, Leiden, The Netherlands 6 Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, U.S.A 7 Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA, U.S.A * These authors contributed equally and share first authorship Correspondence to: Alexander L. Vahrmeijer, email: a.l.vahrmeijer@lumc.nl Keywords: integrins, RGD, fluorescence-guided surgery, preclinical validation, in vivo diagnosis Received: December 15, 2016      Accepted: February 07, 2017      Published: February 18, 2017 ABSTRACT Incomplete resections and damage to critical structures increase morbidity and mortality of patients with cancer. Targeted intraoperative fluorescence imaging aids surgeons by providing real-time visualization of tumors and vital structures. This study evaluated the tumor-targeted zwitterionic near-infrared fluorescent peptide cRGD-ZW800-1 as tracer for intraoperative imaging of multiple cancer types. cRGD-ZW800-1 was validated in vitro on glioblastoma (U-87 MG) and colorectal (HT-29) cell lines. Subsequently, the tracer was tested in orthotopic mouse models with HT-29, breast (MCF-7), pancreatic (BxPC-3), and oral (OSC-19) tumors. Dose-ranging studies, including doses of 0.25, 1.0, 10, and 30 nmol, in xenograft tumor models suggest an optimal dose of 10 nmol, corresponding to a human equivalent dose of 63 μg/kg, and an optimal imaging window between 2 and 24 h post-injection. The mean half-life of cRGD-ZW800-1 in blood was 25 min. Biodistribution at 4 h showed the highest fluorescence signals in tumors and kidneys. In vitro and in vivo competition experiments showed significantly lower fluorescence signals when U-87 MG cells (minus 36%, p = 0.02) or HT-29 tumor bearing mice (TBR at 4 h 3.2 ± 0.5 vs 1.8 ± 0.4, p = 0.03) were simultaneously treated with unlabeled cRGD. cRGD-ZW800-1 visualized in vivo all colorectal, breast, pancreatic, and oral tumor xenografts in mice. Screening for off-target interactions, cRGD-ZW800-1 showed only inhibition of COX-2, likely due to binding of cRGD-ZW800-1 to integrin α V β 3 . Due to its recognition of various integrins, which are expressed on malignant and neoangiogenic cells, it is expected that cRGD-ZW800-1 will provide a sensitive and generic tool to visualize cancer during surgery.

References

30