Acta Oncologica · 2017 · 36 citations · 24 references
MedicineNuclear EngineeringRadiation DosimetryRadiation MeasurementRadiation PhysicsBiological Effects Of RadiationLinear Energy TransferMonte Carlo DosimetryProton DosimetryRadiation Dose MeasurementRelative Biological EffectivenessGafchromic Film DosimetryLet DosimetryLinear Energy Transfer EffectsMonte Carlo Dose SimulationMonte Carlo Radiobiological SimulationRadiation Dose AssessmentRelative Biological Effectiveness DistributionRelative Biological Effectiveness Modeling
Background: In order to determine the relative biological effectiveness (RBE) of protons with high accuracy, radiobiological experiments with detailed knowledge of the linear energy transfer (LET) are needed. Cell survival data from high LET protons are sparse and experiments with low energy protons to achieve high LET values are therefore required. The aim of this study was to quantify LET distributions from a low energy proton beam by using Monte Carlo (MC) simulations, and to further compare to a proton beam representing a typical minimum energy available at clinical facilities.Materials and methods: A Markus ionization chamber and Gafchromic films were employed in dose measurements in the proton beam at Oslo Cyclotron Laboratory. Dose profiles were also calculated using the FLUKA MC code, with the MC beam parameters optimized based on comparisons with the measurements. LET spectra and dose-averaged LET (LETd) were then estimated in FLUKA, and compared with LET calculated from an 80 MeV proton beam.Results: The initial proton energy was determined to be 15.5 MeV, with a Gaussian energy distribution of 0.2% full width at half maximum (FWHM) and a Gaussian lateral spread of 2 mm FWHM. The LETd increased with depth, from approximately 5 keV/μm in the entrance to approximately 40 keV/μm in the distal dose fall-off. The LETd values were considerably higher and the LET spectra were much narrower than the corresponding spectra from the 80 MeV beam.Conclusions: MC simulations accurately modeled the dose distribution from the proton beam and could be used to estimate the LET at any position in the setup. The setup can be used to study the RBE for protons at high LETd, which is not achievable in clinical proton therapy facilities.
24
The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
Till T. Böhlen, F. Cerutti, M. Chin et al. · Nuclear Data Sheets · 2014 · 1.7K citations · Full text
The FLUKA Code: An Accurate Simulation Tool for Particle Therapy
G. Battistoni, Julia Bauer, Till Boehlen et al. · Frontiers in Oncology · 2016 · 259 citations · Full text
Pankaj Chaudhary, Thomas I. Marshall, Francesca Margaret Perozziello et al. · International Journal of Radiation Oncology*Biology*Physics · 2014 · 227 citations · Full text