Clinical Biomechanics · 2017 · 49 citations · 19 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedicsSpinal BiomechanicsSpine SurgeryDegenerative Spine DiseaseFixation BiomechanicsIntervertebral Disc BiomechanicsLumbar Spine BiomechanicsLumbar Spine SurgerySpinal FusionAdjacent Segment MechanicsAdjacent Segment StabilityDegenerative Disc BiomechanicsFinite Element Model ValidationLumbar Degenerative Disc DiseaseLumbar Fusion BiomechanicsLumbar Spinal FusionSpinal Fusion Biomechanics
BACKGROUND DATA: Combined usage of posterior lumbar interbody fusion and transpedicular fixation has been extensively used to treat the various lumbar degenerative disc diseases. The transpedicular fixator aims to increase stability and enhance the fusion rate. However, how the fused disc and bridged vertebrae respectively affect adjacent-segment diseases progression is not yet clear. METHODS: Using a validated lumbosacral finite-element model, three variations at the L4-L5 segment were analyzed: 1) moderate disc degeneration, 2) instrumented with a stand-alone cage and pedicle screw fixators, and 3) with the cage only after fusion. The intersegmental angles, disc stresses, and facet loads were examined. Four motion tests, flexion, extension, bending, and twisting, were also simulated. FINDINGS: The adjacent-segment disease was more severe at the cephalic segment than the caudal segment. After solid fusion and fixation, the increase in intersegmental angles, disc stresses and facet loads of the adjacent segments were about 57.6%, 47.3%, and 59.6%, respectively. However, these changes were reduced to 30.1%, 22.7%, and 27.0% after removal of the fixators. This was attributed to the differences between the biomechanical characteristics of the fusion and fixation mechanisms. INTERPRETATION: Fixation superimposes a stiffer constraint on the mobility of the bridged segment than fusion. The current study suggested that the removal of spinal fixators after complete fusion could decrease the stress at adjacent segments. Through a minimally invasive procedure, we could reduce secondary damage to the paraspinal structures while removing the fixators, which is of utmost concern to surgeons.
19
Adjacent Segment Disease After Posterior Lumbar Interbody Fusion
Hiroaki Nakashima, Noriaki Kawakami, Taichi Tsuji et al. · Spine · 2015 · 185 citations
Risk Factors of Adjacent Segment Disease Requiring Surgery After Lumbar Spinal Fusion
Jae Chul Lee, Yongdai Kim, Jaewan Soh et al. · Spine · 2013 · 180 citations
Failure analysis of broken pedicle screws on spinal instrumentation
Chen-Sheng Chen, Cheng‐Kung Cheng, Shyh-Hua Eric Jao et al. · Medical Engineering & Physics · 2005 · 148 citations