Dental Materials Journal · 2017 · 19 citations · 21 references
DentistryDental Materials ScienceOrthodonticsAnterior Restorative DentistryMechanical Properties Of Dental MaterialsSurface Properties Of Dental MaterialsCrown MaterialsCrown MeasurementRetentive Force AdjustmentRetentive Strength
The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling.