Journal of Pediatric Ophthalmology & Strabismus · 2017 · 11 citations · 10 references
MedicineOphthalmologySurgeryBiomedical OpticsOphthalmic SurgeryStrabismusOphthalmic ImagingOptical Coherence TomographyPediatric StrabismusStrabismus SurgerySurgical Management Of StrabismusIntraoperative ImagingIntraoperative Optical Coherence TomographyLateral Rectus Muscle ResectionLateral Rectus ResectionMuscle ThicknessNeedle Insertion DepthNeedle Penetration DepthPediatric Strabismus Surgery
The authors report the use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT), capable of live four-dimensional (three-dimensional across time) intraoperative imaging, to directly visualize suture depth during lateral rectus resection. Key surgical steps visualized in this report included needle depth during partial and full-thickness muscle passes along with scleral passes. [J Pediatr Ophthalmol Strabismus. 2017;54:e1-e5.].
10
Cheryl Ngo, David R. Smith, Stephen P. Kraft · Journal of American Association for Pediatric Ophthalmology and Strabismus · 2015 · 67 citations