British Journal of Radiology · 2017 · 23 citations · 29 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyGastroenterologyBiliary Tract DiseaseGastrointestinal ImagingHepatobiliary ImagingHepatobiliary SurgeryLiver DiseaseLiver ImagingBile Duct ImagingBile Leak DetectionBiliary Disease ImagingMagnetic Resonance CholangiopancreatographyNon-invasive ExaminationNon-invasive Imaging AssessmentPostoperative Bile LeakPostoperative Biliary Complication Imaging
OBJECTIVE: weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks. METHODS: weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images. RESULTS: In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p < 0.001). 19 of 28 patients had bile leak findings in T1w Gd-EOB-DTPA-enhanced MRC [HBP group: N = 7 (36.8%), DP group: N = 12 (63.2%)]. There was no statistically significant difference in terms of laboratory test results and the presence of bile duct dilatation between HBP and DP group (p > 0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters. CONCLUSION: Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.
29
Analysis of the In Vivo Functions of Mrp3
Martin G. Belinsky, Paul A. Dawson, Irina Shchaveleva et al. · Molecular Pharmacology · 2005 · 167 citations
Frank T. C. Tschirch, Anja Struwe, Henrik Petrowsky et al. · European Radiology · 2008 · 155 citations · Full text
Dirk Domagk, Peter Reimer, Lars Hertel et al. · The American Journal of Gastroenterology · 2004 · 140 citations